4.3.2.6. NXindirecttof

Status:

application definition, extends NXtofraw

Description:

This is a application definition for raw data from a direct geometry TOF spectrometer

Symbols:

The symbol(s) listed here will be used below to coordinate datasets with the same shape.

nDet: Number of detectors

Groups cited:

NXentry, NXinstrument, NXmonochromator

Structure:

entry: (required) NXentry

title: (required) NX_CHAR

start_time: (required) NX_DATE_TIME

definition: (required) NX_CHAR

Official NeXus NXDL schema to which this file conforms

Obligatory value: NXindirecttof

INSTRUMENT: (required) NXinstrument

analyser: (required) NXmonochromator

energy: (required) NX_FLOAT (Rank: 1, Dimensions: [nDet]) {units=NX_ENERGY}

analyzed energy

polar_angle: (required) NX_FLOAT (Rank: 1, Dimensions: [nDet]) {units=NX_ANGLE}

polar angle towards sample

distance: (required) NX_FLOAT (Rank: 1, Dimensions: [nDet]) {units=NX_LENGTH}

distance from sample

Hypertext Anchors

List of hypertext anchors for all groups, fields, attributes, and links defined in this class.

NXDL Source:

https://github.com/nexusformat/definitions/blob/main/applications/NXindirecttof.nxdl.xml